If you are having issues with your foam marker, or it’s not working.Check the list below for common issues with a list of possible fixes.
Issue
The Compressor unit does not work,the warning lights do not turn on.
Causes
1. No Power to control Box
- Check the fuse
- Check the electric connections of the control box
2. Electric connection between control box compressor cut off
- Check the connections between the control box and the electric compressor
Issue
No Foam coming out from the foam marker
Causes
- Tank is not pressurized.
- Close the tank cap properly.
- Check the tightness of the pipes connecting the compressor with the cap.
2. Break in the pneumo/hydraulic Circuit
- Check that there are no cracks in the dark blue pipe inside the tank (from the filter to the plug) and on the outer pipes.Clean the bottom filter of liquid
- Check for any constrictions along the pipes
Issue
Foam Formation is not good
Causes
1. Sponge dirty or hardened
- Clean or replace the sponge in the drop pipe
2. Water-foaming agent mix old
- Redo the water-foaming agent mix
3. Flow-rate adjustment wrong
- Use the flow-rate regulator on the tank cap to obtain a sufficiently dense foam
4. Constrictions in pipes
- Check the tubes to the foam markers
Issue
Bleed Air from the Max. Pressure Valve onto the Plug
Cause
Constrictions in pipes
- Check the tubes to the foam markers
Issue
Air or liquid leaks from the fittings
Cause
Incorrect fitting seal
- Detach the hose at the snap or threaded fittings and shorten itby around 10 mm to eliminate deformations at the fitting.
Issue
The compressor unit does not work, the warning lights flash only once
Cause
+/- power reversed
- Repair the electric connection